311 research outputs found

    Water-filled technique for therapeutic pancreato-biliary EUS in patients with surgically altered anatomy

    Get PDF
    One of the main challenges encountered by endosonographers is performing diagnostic and interventional pancreato-biliary endoscopic ultrasound (EUS) procedures in the presence of surgically altered upper gastrointestinal anatomy. We describe the water-filled technique (WFT) for EUS examination and treatment of the pancreato-biliary region in patients with surgically altered upper gastrointestinal anatomy. Using the WFT, the scope is advanced up to the gastro-jejunal anastomosis and, after placing the tip of the scope 2 cm beyond it, enlargement of the jejunal lumen is obtained by water instillation of the jejunal loop. An enlargement of more than 1.5 cm allows advancement of the tip of the scope under EUSguidance up to the duodenum, in a retrograde way. The WFT is useful for reaching the ampullary area and performing diagnostic and therapeutic EUS in patients with surgically altered anatomy. The technique is also reproducible and can be easily used by endoscopists who regularly perform EUS

    Tips and tricks for the diagnosis and management of biliary stenosis-state of the art review

    Get PDF
    Biliary stenosis may represent a diagnostic and therapeutic challenge resulting in a delay in diagnosis and initiation of therapy due to the frequent difficulty in distinguishing a benign from a malignant stricture. In such cases, the diagnostic flowchart includes the sequential execution of imaging techniques, such as magnetic resonance, magnetic resonance cholangiopancreatography, and endoscopic ultrasound, while endoscopic retrograde cholangiopancreatography is performed to collect tissue for histopathological/cytological diagnosis or to treat the stenosis by insertion of stent. The execution of percutaneous transhepatic drainage with subsequent biopsy has been shown to increase the possibility of tissue diagnosis after failure of the above techniques. Although the diagnostic yield of histopathology and imaging has increased with improvements in endoscopic ultrasound and peroral cholangioscopy, differential diagnosis between malignant and benign stenosis may not be easy in some patients, and strictures are classified as indeterminate. In these cases, a multidisciplinary workup including biochemical marker assays and advanced technologies available may speed up a diagnosis of malignancy or avoid unnecessary surgery in the event of a benign stricture. Here, we review recent advancements in the diagnosis and management of biliary strictures and describe tips and tricks to increase diagnostic yields in clinical routine

    Self-Expanding Metal Stenting for Palliation of Patients with Malignant Colonic Obstruction: Effectiveness and Efficacy on 255 Patients with 12-Month's Follow-up

    Get PDF
    Background. Self-expanding metal stents can alleviate malignant colonic obstruction in incurable patients and avoid palliative stoma surgery. Objective. Evaluate stent effectiveness and safety on palliation of patients with malignant colorectal strictures. Design. Two prospective, one Spanish and one global, multicenter studies. Settings. 39 centers (22 academic, 17 community hospitals) from 13 countries. Patients. A total of 257 patients were enrolled, and 255 patients were treated with a WallFlex uncovered enteral colonic stent. Follow-up was up to 12 months or until death or retreatment. Interventions(s). Self-expanding metal stent placement. Main Outcome Measures. Procedural success, clinical success, and safety. Results. Procedural success was 98.4% (251). Clinical success rates were 87.8% at 30 days, 89.7% at 3 months, 92.8% at 6 months, and 96% at 12 months. Overall perforation rate was 5.1%. Overall migration rate was 5.5%. Overall death rate during follow-up was 48.6% (124), with 67.7% of deaths related to the patient's colorectal cancer, unrelated in 32.3%. Only 2 deaths were related to the stent or procedure. Limitations. No control group. Conclusions. The primary palliative option for patients with malignant colonic obstruction should be self-expanding metal stent placement due to high rates of technical success and efficacy in symptom palliation and few complications

    Lumen-apposing metal stent through the meshes of duodenal metal stents for palliation of malignant jaundice

    Get PDF
    Background and study aims Endoscopic retrograde cholangiopancreatography (ERCP) is the gold standard procedure for malignant jaundice palliation; however, it can be challenging when a duodenal self-expandable metal stent (SEMS) is already in place. Patients and methods The primary aim of our study was to evaluate the technical feasibility of the placement of a lumen apposing metal stent (LAMS) through the mesh (TTM) of duodenal stents. The secondary aims were to evaluate clinical outcomes and adverse events (AEs) related to the procedures. Results Data from 23 patients (11 F and 12 M; mean age: 69.5 ± 11 years old) were collected. In 17 patients (73.9 %) TTM LAMS placement was performed as first intention, while in six patients (26.1 %) it was performed after a failed ERCP. Thirteen patients (56.5 %) underwent the procedure due to advanced pancreatic head neoplasia. One technical failure was experienced (4.3 %). The TTM LAMS placement led to a significant decrease in the serum levels of bilirubin, ALP, GGT, WBC and CRP. No cases of duodenal SEMS occlusion occurred and no other AEs were observed during the follow-up. Conclusions Concomitant malignant duodenal and biliary obstruction is a challenging condition. Palliation of jaundice using TTM LAMS in patients already treated with duodenal stent is associated to promising technical and clinical outcomes

    International multicenter expert survey on endoscopic treatment of upper gastrointestinal anastomotic leaks

    Get PDF
    Background and study aims: A variety of endoscopic techniques are currently available for treatment of upper gastrointestinal (UGI) anastomotic leaks; however, no definite consensus exists on the most appropriate therapeutic approach. Our aim was to explore current management of UGI anastomotic leaks. Methods: A survey questionnaire was distributed among international expert therapeutic endoscopists regarding management of UGI anastomotic leaks. Results: A total of 44 % of 163 surveys were returned; 69 % were from gastroenterologists and 56 % had > 10 years of experience. A third of respondents treat between 10 and 19 patients annually. Fifty-six percent use fully-covered self-expandable metal stents as their usual first option; 80% use techniques to minimize migration; 4 weeks was the most common reported stent dwell time. Sixty percent perform epithelial ablation prior to over-the-scope-clip placement or suturing. Regarding endoscopic vacuum therapy (EVT), 56 % perform balloon dilation and intracavitary EVT in patients with large cavities but small leak defects. Regarding endoscopic septotomy, 56 % consider a minimal interval of 4 weeks from surgery and 90 % consider the need to perform further sessions. Regarding endoscopic internal drainage (EID), placement of two stents and shorter stents is preferred. Persistent inflammation with clinical sepsis was the definition most commonly reported for endoscopic failure. EVT/stent placement and EVT/EID were the therapeutic options most often chosen in patients with previous oncologic surgery and previous bariatric surgery, respectively. Conclusions: There is a wide variation in the management of patients with UGI anastomotic leaks. Future prospective studies are needed to move from an expert- to evidence- and personalization-based care

    High-definition colonoscopy versus Endocuff versus EndoRings versus Full-Spectrum Endoscopy for adenoma detection at colonoscopy: a multicenter randomized trial

    Get PDF
    Background Devices used to improve polyp detection during colonoscopy have seldom been compared with each other. Methods We performed a 3-center prospective randomized trial comparing high-definition (HD) forward-viewing colonoscopy alone to HD with Endocuff to HD with EndoRings to the Full Spectrum Endoscopy (FUSE) system. Patients were age ≥50 years and had routine indications and intact colons. The study colonoscopists were all proven high-level detectors. The primary endpoint was adenomas per colonoscopy (APC) Results Among 1,188 patients who completed the study, APC with Endocuff (APC Mean ± SD 1.82 ± 2.58), EndoRings (1.55 ± 2.42), and standard HD colonoscopy (1.53 ± 2.33) were all higher than FUSE (1.30 ± 1.96,) (p<0.001 for APC). Endocuff was higher than standard HD colonoscopy for APC (p=0.014) . Mean cecal insertion times with FUSE (468 ± 311 seconds) and EndoRings (403 ± 263 seconds) were both longer than with Endocuff (354 ± 216 seconds) (p=0.006 and 0.018, respectively). Conclusions For high-level detectors at colonoscopy, forward-viewing HD instruments dominate the FUSE system, indicating that for these examiners image resolution trumps angle of view. Further, Endocuff is a dominant strategy over EndoRings and no mucosal exposure device on a forward-viewing HD colonoscope
    corecore